UA-Hub-DoorMechanical | |||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dimensions | 174.9 x 126 x 32.9 mm (6.9 x 5 x 1.3") | ||||||||||||||||||||||||
Weight | 363 g (12.8 oz) | ||||||||||||||||||||||||
Enclosure material | Polycarbonate | ||||||||||||||||||||||||
Mounting material | Polycarbonate | ||||||||||||||||||||||||
Hardware | |||||||||||||||||||||||||
Networking interface | (5) 10/100/1000 Base-T | ||||||||||||||||||||||||
Power method | PoE++ UL 294 Power-limited Class 2 PSU UL 60950-1/62368-1 LPS/PS2 PSU | ||||||||||||||||||||||||
Max. power consumption | Without PoE output: 30W With PoE output: 50W | ||||||||||||||||||||||||
PoE input | 50V DC, 1A | ||||||||||||||||||||||||
PoE output | (4) PoE, 50V DC, 15.4W each port Max. 28W aggregated | ||||||||||||||||||||||||
LEDs | White/blue (Learn more) | ||||||||||||||||||||||||
Button | (1) Factory-reset | ||||||||||||||||||||||||
Digital input | Request to exit/request to enter/remote release/door position sensor | ||||||||||||||||||||||||
Dry output relay | Lock: 30V DC, 1A Aux: 30V DC, 1A | ||||||||||||||||||||||||
Powered output relay | Lock: 12V DC, 1A Aux: 12V DC, 0.33A 12V DC, 0.33A | ||||||||||||||||||||||||
Operating environment | Indoor use only | ||||||||||||||||||||||||
Ambient operating temperature | 0 to 40° C (32 to 104° F) | ||||||||||||||||||||||||
Ambient operating humidity | 5 to 95% noncondensing | ||||||||||||||||||||||||
UL 294 level | Destructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level I | ||||||||||||||||||||||||
UL 294 statement | Compliance with IEEE 802.3 (at or af) specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits. | ||||||||||||||||||||||||
CAN/ULC-60839-11-1 Grade | Grade assignment: 1 | ||||||||||||||||||||||||
Certifications | CE, FCC, IC, UL 294, CAN/ULC-60839-11-1 | ||||||||||||||||||||||||
Wiring Information | |||||||||||||||||||||||||
Wiring gauge requirements (AWG) |
UACC-Cable-DoorLockRelay (18 AWG) is recommended. | ||||||||||||||||||||||||
PoE cabling requirements | The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 24 AWG (0.21 mm 2 ) for horizontal or riser cable. | ||||||||||||||||||||||||
UA-G3-ProMechanical | |||||||||||||||||||||||||
Dimensions | 160 x 40.4 x 40.55 mm (6.3 x 1.59 x 1.6") | ||||||||||||||||||||||||
Weight | 136 g (4.8 oz) | ||||||||||||||||||||||||
Enclosure material | Polycarbonate, glass | ||||||||||||||||||||||||
Mount material | Aluminum alloy | ||||||||||||||||||||||||
Mounting | Wall mount (Included) Gangbox mount (Included) Angle mount (Optional) Junction box (Optional) | ||||||||||||||||||||||||
Weatherproofing | IP55 | ||||||||||||||||||||||||
Hardware | |||||||||||||||||||||||||
Networking interface | (1) GbE RJ45 port | ||||||||||||||||||||||||
Connectivity | BLE 4.2 NFC | ||||||||||||||||||||||||
Power method | PoE UL 294 Power-limited Class 2 PSU UL 60950-1/62368-1 LPS/PS2 PSU | ||||||||||||||||||||||||
Supported voltage range | 48V DC | ||||||||||||||||||||||||
Max. power consumption | 6W | ||||||||||||||||||||||||
ESD/EMP protection | Air: ±15kV, contact: ±8kV | ||||||||||||||||||||||||
Sensor | Proximity sensor | ||||||||||||||||||||||||
Camera view angle | H: 96.67°, V: 123.15°, D: 153.11° | ||||||||||||||||||||||||
Microphone | Yes | ||||||||||||||||||||||||
Speaker | (1) 4 ohm, 1.5W | ||||||||||||||||||||||||
LEDs | R/G/B/W/Amber (Learn more) | ||||||||||||||||||||||||
Button | (1) Factory-reset | ||||||||||||||||||||||||
NFC frequency | 13.56 MHz | ||||||||||||||||||||||||
NFC read range | < 30 mm | ||||||||||||||||||||||||
NFC technology | ISO/IEC 14443A / 14443B / 15693 / 18092 (Ecma 340) MIFARE Classic / MIFARE DESFIRE Sony FeliCa™ (ID only) NFC Forum tags T1T, T2T, T3T, T4T and T5T ECP 2.0 | ||||||||||||||||||||||||
Operating environment | Outdoor use | ||||||||||||||||||||||||
Ambient operating temperature | Device: -30 to 45° C (-22 to 113° F) Display:* -10 to 45° C (14 to 113° F) *The display will turn off when the ambient temperature is above/below the display operation temperature, but other functions will remain functional. (Effective after firmware v1.3.28) | ||||||||||||||||||||||||
Ambient operating humidity | 5 to 90% noncondensing | ||||||||||||||||||||||||
Software information | The software version of a product can be checked at https://unifi.ui.com | ||||||||||||||||||||||||
UL 294 level | Destructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level I | ||||||||||||||||||||||||
UL 294 statement | Compliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits. | ||||||||||||||||||||||||
PoE cabling requirements | Cat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm 2 ) for patch cords; 24 AWG (0.21 mm 2 ) for horizontal or riser cable. | ||||||||||||||||||||||||
CAN/ULC-60839-11-1 Grade | Grade assignment: I | ||||||||||||||||||||||||
Certifications | CE, FCC, IC, UL 294, CAN/ULC-60839-11-1 | ||||||||||||||||||||||||
Document number, and issue date and/or revision level | UA-G3-Pro-W/UA-G3-Pro-B, V01 | ||||||||||||||||||||||||
Software | |||||||||||||||||||||||||
Management application | UniFi Access: Version 3.0.15 and later | ||||||||||||||||||||||||
UA-G3Mechanical | |||||||||||||||||||||||||
Dimensions | 93 x 40 x 36.5 mm (3.7 x 1.6 x 1.4") | ||||||||||||||||||||||||
Weight | 82 g (2.9 oz) | ||||||||||||||||||||||||
Enclosure material | Polycarbonate, glass | ||||||||||||||||||||||||
Mounting material | Aluminum alloy | ||||||||||||||||||||||||
Mounting | In wall, gang box | ||||||||||||||||||||||||
Weatherproofing | IP55 | ||||||||||||||||||||||||
Hardware | |||||||||||||||||||||||||
Networking interface | (1) 10/100 MbE RJ45 port | ||||||||||||||||||||||||
Connectivity | BLE 4.1 NFC | ||||||||||||||||||||||||
Power method | PoE UL 294 Power-limited Class 2 PSU UL 60950-1/62368-1 LPS/PS2 PSU | ||||||||||||||||||||||||
Supported voltage range | 48V DC | ||||||||||||||||||||||||
Max. power consumption | 5W | ||||||||||||||||||||||||
ESD/EMP protection | Air: ±15kV, contact: ±8kV | ||||||||||||||||||||||||
Sensors | Proximity sensor | ||||||||||||||||||||||||
Speaker | (1) 8 ohm, 0.7W | ||||||||||||||||||||||||
LEDs | R/G/B/W (Learn more) | ||||||||||||||||||||||||
Button | (1) Factory-reset | ||||||||||||||||||||||||
NFC frequency | 13.56 MHz | ||||||||||||||||||||||||
NFC read range | < 30 mm | ||||||||||||||||||||||||
NFC technology | ISO/IEC 14443A / 14443B / 15693 / 18092 (Ecma 340) MIFARE Classic / MIFARE DESFIRE Sony FeliCa™ (ID only) NFC Forum tags T1T, T2T, T3T, T4T and T5T ECP 2.0 | ||||||||||||||||||||||||
Operating environment | Outdoor use | ||||||||||||||||||||||||
Ambient operating temperature | -30 to 45° C (-22 to 113° F) | ||||||||||||||||||||||||
Ambient operating humidity | 5 to 90% noncondensing | ||||||||||||||||||||||||
Software information | The software version of a product can be checked at https://unifi.ui.com | ||||||||||||||||||||||||
UL 294 level | Destructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level I | ||||||||||||||||||||||||
UL 294 statement | Compliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits. | ||||||||||||||||||||||||
PoE cabling requirements | Cat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm 2 ) for patch cords; 24 AWG (0.21 mm 2 ) for horizontal or riser cable. | ||||||||||||||||||||||||
CAN/ULC-60839-11-1 Grade | Grade assignment: I | ||||||||||||||||||||||||
Certifications | CE, FCC, IC, UL 294, CAN/ULC-60839-11-1 | ||||||||||||||||||||||||
UA-PocketMechanical | |||||||||||||||||||||||||
Dimensions | 84 x 39 x 7.4 mm (3.3 x 1.5 x 0.3") | ||||||||||||||||||||||||
Weight | 16 g (0.56 oz) | ||||||||||||||||||||||||
Enclosure material | Polycarbonate, stainless steel, silicone rubber | ||||||||||||||||||||||||
Weatherproofing | IP54 | ||||||||||||||||||||||||
Hardware | |||||||||||||||||||||||||
NFC frequency | 13.56 MHz | ||||||||||||||||||||||||
NFC technology | ISO/IEC 14443 Type A MIFARE DESFire EV3 4K UniFi Access Proprietary Security Protocol | ||||||||||||||||||||||||
Ambient operating temperature | -10 to 45° C (14 to 113° F) | ||||||||||||||||||||||||
Ambient operating humidity | 10 to 90% noncondensing | ||||||||||||||||||||||||
Certification | CE |